{"id":960,"date":"2025-04-27T11:22:09","date_gmt":"2025-04-27T11:22:09","guid":{"rendered":"https:\/\/saltoecologico.es\/?page_id=960"},"modified":"2025-04-27T11:22:11","modified_gmt":"2025-04-27T11:22:11","slug":"la-garita-resumen","status":"publish","type":"page","link":"https:\/\/saltoecologico.es\/index.php\/la-garita-resumen\/","title":{"rendered":"La Garita resumen"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>Proyecto:<\/strong> Planta de Generaci\u00f3n con Grupos de Emergencia 14,8 MW &#8211; Planta La Garita (Salinetas)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Promotor:<\/strong> DISA GENERACI\u00d3N S.L.U. (CIF: B-19817535), con domicilio en C\/ \u00c1lvaro Rodr\u00edguez L\u00f3pez 1, 38003 Santa Cruz de Tenerife.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Ubicaci\u00f3n:<\/strong> Pol\u00edgono 1, Parcela 120 (Ref. Catastral 35026A001001200000RU), Salinetas, 35214 Telde, Las Palmas, Gran Canaria.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Contexto y Justificaci\u00f3n:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">El proyecto se desarrolla en respuesta a la invitaci\u00f3n de la Consejer\u00eda de Transici\u00f3n Ecol\u00f3gica y Energ\u00eda de Canarias para cubrir las necesidades de generaci\u00f3n de emergencia, tras informes del Operador del Sistema (REE) que alertaban sobre riesgos en la cobertura de la demanda el\u00e9ctrica en Gran Canaria. La adjudicaci\u00f3n a DISA forma parte de las medidas extraordinarias (amparadas por el RD 738\/2015) para garantizar el suministro el\u00e9ctrico insular, actuando como un refuerzo temporal mientras se desarrollan soluciones estructurales a largo plazo (renovaci\u00f3n de equipos, almacenamiento energ\u00e9tico). Dada su naturaleza estrat\u00e9gica y de inter\u00e9s general, se aplica la tramitaci\u00f3n de urgencia.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Objeto Principal:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">El objetivo es obtener las autorizaciones administrativas para construir y operar una planta de generaci\u00f3n el\u00e9ctrica de 14,8 MW mediante grupos de emergencia en Salinetas. La planta est\u00e1 dise\u00f1ada para operar autom\u00e1ticamente en caso de fallos en la red principal, garantizando la estabilidad del sistema. Utilizar\u00e1 propano como combustible, destacando que esta tecnolog\u00eda es un 22% m\u00e1s eficiente y reduce las emisiones en un 35% respecto al fuel\/gasoil, y es compatible con biopropano e hidr\u00f3geno (hasta 75%).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Alcance del Proyecto:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">El proyecto incluye el dise\u00f1o e instalaci\u00f3n de:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u00c1rea de Almacenamiento:<\/strong>\n<ul class=\"wp-block-list\">\n<li>Una nueva esfera de 1.000 m\u00b3 de propano (en instalaciones adyacentes de DISA).<\/li>\n\n\n\n<li>Dos dep\u00f3sitos horizontales existentes de 200 m\u00b3 de propano cada uno (capacidad total 400 m\u00b3 en la planta).<\/li>\n\n\n\n<li>Conexi\u00f3n de la esfera con el parque de almacenamiento existente.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Grupo de Motores:<\/strong>\n<ul class=\"wp-block-list\">\n<li>Ocho (8) motores-generadores modulares (MWM TCG3020 V20 Z o similar) con una potencia nominal total de 14,8 MW, incluyendo sus sistemas auxiliares.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Servicios Auxiliares:<\/strong>\n<ul class=\"wp-block-list\">\n<li>Dep\u00f3sito y grupo de bombeo para protecci\u00f3n contra incendios (PCI).<\/li>\n\n\n\n<li>Edificio de servicios auxiliares (Utilities) de 60 m\u00b2.<\/li>\n\n\n\n<li>Sistema de control distribuido (DCS).<\/li>\n\n\n\n<li>Instalaci\u00f3n el\u00e9ctrica BT (iluminaci\u00f3n exterior LED, pararrayos, red de tierras, servicios auxiliares).<\/li>\n\n\n\n<li>Redes de saneamiento (fecales y pluviales) y drenajes.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Subestaci\u00f3n El\u00e9ctrica (SET) y Conexi\u00f3n a Red:<\/strong>\n<ul class=\"wp-block-list\">\n<li>Nueva subestaci\u00f3n elevadora \u00abSET CINSA 66\/11 kV\u00bb (ocupando 1.000 m\u00b2).<\/li>\n\n\n\n<li>L\u00ednea subterr\u00e1nea de alta tensi\u00f3n (LSAT) de 66 kV para conexi\u00f3n con la subestaci\u00f3n CINSA-REE existente.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Descripci\u00f3n T\u00e9cnica Detallada:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Emplazamiento:<\/strong> La parcela (22.601 m\u00b2) se sit\u00faa en la Zona Industrial de Salinetas, Telde. La superficie de actuaci\u00f3n es de 9.187 m\u00b2. El terreno es Suelo R\u00fastico de Protecci\u00f3n de Entornos (PEN), pero se justifica el uso industrial\/energ\u00e9tico por inter\u00e9s general (Ley 4\/2017 del Suelo). Se encuentra cerca de la autopista GC-1 y del aeropuerto.<\/li>\n\n\n\n<li><strong>Generaci\u00f3n:<\/strong> 8 motores-generadores MWM TCG3020 V20 Z (o similar) de 1.880 kWe cada uno, ciclo Otto, optimizados para propano. Tensi\u00f3n de generaci\u00f3n 11 kV.<\/li>\n\n\n\n<li><strong>Almacenamiento Propano:<\/strong> Adem\u00e1s de la esfera de 1.000 m\u00b3 en la instalaci\u00f3n adyacente, la planta cuenta con 2 dep\u00f3sitos horizontales de 200 m\u00b3 cada uno, con vaporizadores internos y m\u00f3dulos de calefacci\u00f3n. Cumplen ITC-ICG-03 y UNE 60250.<\/li>\n\n\n\n<li><strong>Infraestructura Civil:<\/strong> Incluye acondicionamiento del terreno (desbroce, nivelaci\u00f3n), cimentaciones espec\u00edficas para motores (losa HA-30) y dep\u00f3sitos (muros\/zapatas HA-30), edificio de utilities (60 m\u00b2), urbanizaci\u00f3n (viales de hormig\u00f3n HA-25, zonas de maniobra, jardiner\u00eda), saneamiento separativo (pluviales y fecales con fosa s\u00e9ptica) y cierre perimetral (malla simple torsi\u00f3n y puerta corredera motorizada).<\/li>\n\n\n\n<li><strong>Instalaciones Auxiliares:<\/strong>\n<ul class=\"wp-block-list\">\n<li>PCI: Red de hidrantes, detecci\u00f3n autom\u00e1tica (gas\/humo), pulsadores manuales, alarma ac\u00fastica, extintores (polvo ABC, CO2, carros), sistema de agua pulverizada autom\u00e1tico para refrigeraci\u00f3n de dep\u00f3sitos. Abastecimiento categor\u00eda I (UNE 23500) con tanque y grupo de bombeo (el\u00e9ctrica+di\u00e9sel+jockey).<\/li>\n\n\n\n<li>Sistema de Control (DCS): Control distribuido con controladores redundantes (proceso, ESD, F&amp;G), sala de control local, integraci\u00f3n de subsistemas (almacenamiento, motores, SET, conexi\u00f3n red) v\u00eda Modbus TCP o similar.<\/li>\n\n\n\n<li>Instalaci\u00f3n El\u00e9ctrica BT: Suministro desde SET, iluminaci\u00f3n exterior LED, pararrayos PDC Nivel I (UNE 21186), red de tierras (&lt;80 ohmios, independiente para protecci\u00f3n cat\u00f3dica), servicios auxiliares. Cumple REBT (ITC-BT-18, 19, 20, 21, 29).<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Conexi\u00f3n a Red (SET CINSA 66\/11 kV):<\/strong> Subestaci\u00f3n elevadora intemperie\/interior con aparamenta de 66 kV (interruptor SF6, seccionador PAT, TTs, TIs, autov\u00e1lvulas) y 11 kV (celdas blindadas SF6: 8 l\u00ednea, 1 reserva, 1 trafo potencia, 1 SS.AA.\/medida). Conexi\u00f3n a CINSA-REE mediante LSAT 66 kV subterr\u00e1nea (cable RHZ1-RA+2OL(S) 36\/66 kV 1&#215;1000 KAl + H95).<\/li>\n\n\n\n<li><strong>Seguridad y Salud:<\/strong> Se incluye un Estudio de Seguridad y Salud detallado, analizando riesgos por fases (movimiento tierras, cimentaci\u00f3n, montaje, etc.) y oficios, especificando protecciones colectivas (vallado, se\u00f1alizaci\u00f3n, redes, etc.) e individuales (casco, guantes, arn\u00e9s, etc.), instalaciones de higiene (vestuarios, aseos, comedor), medios de primeros auxilios y medidas contra incendios.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Marco Regulatorio:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">El proyecto cumple con la normativa sectorial el\u00e9ctrica (Ley 24\/2013, RD 738\/2015, RD 1955\/2000, RD 337\/2014, RD 223\/2008, REBT), de seguridad industrial (RSCIEI, RIPCI, ITC-ICG-03, Reglamento Equipos a Presi\u00f3n), urban\u00edstica (PGO Telde, Ley 4\/2017 Suelo Canarias) y medioambiental (Ley 7\/2022 Residuos, Ley 21\/2013 Evaluaci\u00f3n Ambiental).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Conclusi\u00f3n:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Este proyecto detalla la construcci\u00f3n de una planta de generaci\u00f3n de emergencia de 14,8 MW en Salinetas, promovida por DISA, como medida temporal y estrat\u00e9gica para reforzar la seguridad del suministro el\u00e9ctrico en Gran Canaria, utilizando tecnolog\u00eda de motores a propano eficiente y adaptable a futuros combustibles renovables, cumpliendo con toda la normativa t\u00e9cnica y de seguridad aplicable.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Proyecto: Planta de Generaci\u00f3n con Grupos de Emergencia 14,8 MW &#8211; Planta La Garita (Salinetas) Promotor: DISA GENERACI\u00d3N S.L.U. (CIF: B-19817535), con domicilio en C\/ \u00c1lvaro Rodr\u00edguez L\u00f3pez 1, 38003 Santa Cruz de Tenerife. Ubicaci\u00f3n: Pol\u00edgono 1, Parcela 120 (Ref. Catastral 35026A001001200000RU), Salinetas, 35214 Telde, Las Palmas, Gran Canaria. Contexto y Justificaci\u00f3n: El proyecto se [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-960","page","type-page","status-publish"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>La Garita resumen - Salto Ecol\u00f3gico<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/saltoecologico.es\/index.php\/la-garita-resumen\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"La Garita resumen - Salto Ecol\u00f3gico\" \/>\n<meta property=\"og:description\" content=\"Proyecto: Planta de Generaci\u00f3n con Grupos de Emergencia 14,8 MW &#8211; Planta La Garita (Salinetas) Promotor: DISA GENERACI\u00d3N S.L.U. (CIF: B-19817535), con domicilio en C\/ \u00c1lvaro Rodr\u00edguez L\u00f3pez 1, 38003 Santa Cruz de Tenerife. Ubicaci\u00f3n: Pol\u00edgono 1, Parcela 120 (Ref. Catastral 35026A001001200000RU), Salinetas, 35214 Telde, Las Palmas, Gran Canaria. Contexto y Justificaci\u00f3n: El proyecto se [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/saltoecologico.es\/index.php\/la-garita-resumen\/\" \/>\n<meta property=\"og:site_name\" content=\"Salto Ecol\u00f3gico\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/Saltotransicionecologica\" \/>\n<meta property=\"article:modified_time\" content=\"2025-04-27T11:22:11+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/saltoecologico.es\\\/index.php\\\/la-garita-resumen\\\/\",\"url\":\"https:\\\/\\\/saltoecologico.es\\\/index.php\\\/la-garita-resumen\\\/\",\"name\":\"La Garita resumen - Salto Ecol\u00f3gico\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/saltoecologico.es\\\/#website\"},\"datePublished\":\"2025-04-27T11:22:09+00:00\",\"dateModified\":\"2025-04-27T11:22:11+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/saltoecologico.es\\\/index.php\\\/la-garita-resumen\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/saltoecologico.es\\\/index.php\\\/la-garita-resumen\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/saltoecologico.es\\\/index.php\\\/la-garita-resumen\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Portada\",\"item\":\"https:\\\/\\\/saltoecologico.es\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"La Garita resumen\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/saltoecologico.es\\\/#website\",\"url\":\"https:\\\/\\\/saltoecologico.es\\\/\",\"name\":\"Salto Ecol\u00f3gico\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/saltoecologico.es\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/saltoecologico.es\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/saltoecologico.es\\\/#organization\",\"name\":\"Salto a la Transici\u00f3n Ecol\u00f3gica\",\"url\":\"https:\\\/\\\/saltoecologico.es\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/saltoecologico.es\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/saltoecologico.es\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/Logo-STE.jpg\",\"contentUrl\":\"https:\\\/\\\/saltoecologico.es\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/Logo-STE.jpg\",\"width\":435,\"height\":435,\"caption\":\"Salto a la Transici\u00f3n Ecol\u00f3gica\"},\"image\":{\"@id\":\"https:\\\/\\\/saltoecologico.es\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/Saltotransicionecologica\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"La Garita resumen - Salto Ecol\u00f3gico","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/saltoecologico.es\/index.php\/la-garita-resumen\/","og_locale":"es_ES","og_type":"article","og_title":"La Garita resumen - Salto Ecol\u00f3gico","og_description":"Proyecto: Planta de Generaci\u00f3n con Grupos de Emergencia 14,8 MW &#8211; Planta La Garita (Salinetas) Promotor: DISA GENERACI\u00d3N S.L.U. (CIF: B-19817535), con domicilio en C\/ \u00c1lvaro Rodr\u00edguez L\u00f3pez 1, 38003 Santa Cruz de Tenerife. Ubicaci\u00f3n: Pol\u00edgono 1, Parcela 120 (Ref. Catastral 35026A001001200000RU), Salinetas, 35214 Telde, Las Palmas, Gran Canaria. Contexto y Justificaci\u00f3n: El proyecto se [&hellip;]","og_url":"https:\/\/saltoecologico.es\/index.php\/la-garita-resumen\/","og_site_name":"Salto Ecol\u00f3gico","article_publisher":"https:\/\/www.facebook.com\/Saltotransicionecologica","article_modified_time":"2025-04-27T11:22:11+00:00","twitter_card":"summary_large_image","twitter_misc":{"Tiempo de lectura":"4 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/saltoecologico.es\/index.php\/la-garita-resumen\/","url":"https:\/\/saltoecologico.es\/index.php\/la-garita-resumen\/","name":"La Garita resumen - Salto Ecol\u00f3gico","isPartOf":{"@id":"https:\/\/saltoecologico.es\/#website"},"datePublished":"2025-04-27T11:22:09+00:00","dateModified":"2025-04-27T11:22:11+00:00","breadcrumb":{"@id":"https:\/\/saltoecologico.es\/index.php\/la-garita-resumen\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/saltoecologico.es\/index.php\/la-garita-resumen\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/saltoecologico.es\/index.php\/la-garita-resumen\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/saltoecologico.es\/"},{"@type":"ListItem","position":2,"name":"La Garita resumen"}]},{"@type":"WebSite","@id":"https:\/\/saltoecologico.es\/#website","url":"https:\/\/saltoecologico.es\/","name":"Salto Ecol\u00f3gico","description":"","publisher":{"@id":"https:\/\/saltoecologico.es\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/saltoecologico.es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/saltoecologico.es\/#organization","name":"Salto a la Transici\u00f3n Ecol\u00f3gica","url":"https:\/\/saltoecologico.es\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/saltoecologico.es\/#\/schema\/logo\/image\/","url":"https:\/\/saltoecologico.es\/wp-content\/uploads\/2025\/04\/Logo-STE.jpg","contentUrl":"https:\/\/saltoecologico.es\/wp-content\/uploads\/2025\/04\/Logo-STE.jpg","width":435,"height":435,"caption":"Salto a la Transici\u00f3n Ecol\u00f3gica"},"image":{"@id":"https:\/\/saltoecologico.es\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/Saltotransicionecologica"]}]}},"_links":{"self":[{"href":"https:\/\/saltoecologico.es\/index.php\/wp-json\/wp\/v2\/pages\/960","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/saltoecologico.es\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/saltoecologico.es\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/saltoecologico.es\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/saltoecologico.es\/index.php\/wp-json\/wp\/v2\/comments?post=960"}],"version-history":[{"count":1,"href":"https:\/\/saltoecologico.es\/index.php\/wp-json\/wp\/v2\/pages\/960\/revisions"}],"predecessor-version":[{"id":961,"href":"https:\/\/saltoecologico.es\/index.php\/wp-json\/wp\/v2\/pages\/960\/revisions\/961"}],"wp:attachment":[{"href":"https:\/\/saltoecologico.es\/index.php\/wp-json\/wp\/v2\/media?parent=960"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}